Welcome to BNA company!

No. 1688, Gaoke East Road,Shanghai, China.

Call us anytime

0086-21-58386256

Opeening Time

Mon-Sat: 8.30-18.00

Freund-Vector | Your Global Equipment and Processing Solution

Headquartered are in Marion, IA, Freund-Vector formulates processing solutions and provides equipment to companies worldwide. Come see for yourself.

Used- Alexanderwerk Roller Compactor, model WP120

Used- Alexanderwerk Roller Compactor, model WP120V Pharma, stainless steel. Horizontal screw feeder with pre-breaker, cantilevered rolls, flake crusher, pre-granulator and fine granulator attachments, rated +/- 5g batch, 8 - 40 kg/hour continuous, Siemens Simatic multi panels operation with operator control panel, portable design, unit designed for soft wall isolator with framework, machine # ...

PULL TYPE TANDEM FERT. SPREADER W ROLL TARP Other For …

Browse our inventory of new and used PULL TYPE TANDEM FERT. SPREADER W ROLL TARP Other For Sale near you at TractorHouse.com. Models include . Page 1 of 1.

(PDF) Journal of Global Pharma Technology Influence of ...

an Alexanderwerk WP120 (Alexanderwerk, Germany) roller compactor. D uring studi es. variables were hydraulic pressure, ... The model . of the second order for two factors is showed .

Used- Alexanderwerk WP 50 304 Stainless Steel Roll ...

We make this quick and easy! Used- Alexanderwerk WP 50 304 Stainless Steel Roll Compactor System consisting of: (1) Model WP 50 roller compactor. (2) 152 mm (5.98") diameter x 75 mm (2.95") face 410/16/20 stainless steel smooth style cored rolls, approximate capacity up to 120 kg/hr, driven by a 1.5/2.2 kw, 3/50/680 volt motor, approximate roll ...

BMA group - pre-owned machines (bmagrouppreownedmachines ...

BMA group - pre-owned machines | The BMA Group - Bischoff & Munneke can draw upon 40 years of second-generation experience in the worldwide trade of pre-owned machines.

Instrumented roll technology for the design space ...

Instrumented roll technology on Alexanderwerk ® WP120 roller compactor was developed and utilized successfully for the measurement of normal stress on ribbon during the process. The effects of process parameters such as roll speed (4–12 rpm), feed screw speed (19–53 rpm), and hydraulic roll pressure (40–70 bar) on normal stress and ribbon density were studied using placebo …

Used Alexanderwerk for sale. Top quality machinery ...

Alexanderwerk PP175X90 Roller Compactor, S/S. Manufacturer: Alexanderwerk; Used Alexanderwerk Roller Compactor, model PP175x90, stainless steel product contact surfaces, 175 mm diameter x 90 mm roll face rolls, 30 Kn roll force, with agitated …

Roll Compactors & Dry Compacting Equipment for Sale

Roller compactors or chilsonators allow the product to be dry granulated and provide an increased density and subsequently easier flowability. Examples of Roll Compaction equipment we buy and sell includes the following models made by Alexanderwerk: Roller Compactor BT 120 Pharma, Roller Compactor PP 150, Roller Compactor PP 175, Roller ...

compactor for pharmaceutical industry

Compactor for the pharmaceutical industry for research Find out all of the information about the Alexanderwerk product compactor for the pharmaceutical industry for research and development roller WP 120 Pharma Contact a supplier or the parent company directly to get a quote or to find out a price or your closest point of sale ... machine for ...

CIRCLE Other For Sale In Pennsylvania - 1 Listings ...

Browse our inventory of new and used CIRCLE Other For Sale In Pennsylvania at TractorHouse.com. Models include GRAIN BIN. Page 1 of 1.

The effect of lubrication on density distributions of ...

Instrumented roll technology on Alexanderwerk® WP120 roller compactor was developed and utilized successfully for the measurement of normal stress on ribbon during the process.

Pharmaceutics | Free Full-Text | Model-Based Scale-up ...

A study comparing the density results of actual experiments using the FEM model and the Alexanderwerk WP120 roll compactor (Alexanderwerk , Germany) was conducted. To improve the accuracy of the model, the boundary conditions of the model were determined using experimentally measured values.

(PDF) Optimization of Roll Compaction/Dry Granulation ...

The RCDG was conducted on a pre-qualified (qualified for installation, operational and performance qualification) Alexanderwerk, model WP 120 Pharma (Alexanderwerk AG, Germany) roll compactor. The knurled rolls of 120 mm in diameter and 40 mm in width were used for roll compaction. The process parameters used for optimization studies are ...

Validation of 3-D finite element analysis for predicting ...

Microcrystalline cellulose (Avicel PH-102, FMC BioPolymers, PA, USA) powder was roll-compacted using an Alexanderwerk WP120-40V (Alexanderwerk , Germany), a lab-scale roller compactor with 12 cm diameter, knurled rolls.

Narrowing the gap between clinical capsule formulations ...

The active was blended as above with all excipients except magnesium stearate. The powder mixture was then compacted into hard ribbons on a roller compactor (Alexanderwerk WP120; Alexanderwerk Inc., PA, USA) set at 5 rpm roll speed, 30 bar roll pressure, 36 rpm feed screw speed and 2 mm roll gap.

2021 12FT SHIPPING CONTAINER W/ ROLL UP DOOR Other For ...

Browse our inventory of new and used 2021 12FT SHIPPING CONTAINER W/ ROLL UP DOOR Other For Sale near you at TractorHouse.com. Models include . Page 1 of 1.

Narrowing the gap between clinical capsule formulations ...

compactor (Alexanderwerk WP120; Alexanderwerk Inc., PA, USA) set at 5 rpm roll speed, 30 bar roll pressure, 36 rpm feed screw speed and 2 mm roll gap. The ribbons were milled through a Quadro Comil U5 (Quadro, Canada) set at 1500 2500 rpm impeller speed and using a 0.050 0.079 in. grater screen. The resulting granules were then

2012 BW211D-40 SMOOTH DRUM COMPACTOR Other …

Browse our inventory of new and used 2012 BW211D-40 SMOOTH DRUM COMPACTOR Other For Sale near you at TractorHouse.com. Models include . Page 1 of 1.

as Filler/Binder/Disintegrant in a Roller Compaction Dry ...

make a pre-compaction blend. The above mixture was compacted on an Alexanderwerk-WP 120 roller compactor using 40 mm knurled surface rolls, set up at 40-bar pressure, feed screw speed of 40 rpm and roll speed of 7 rpm. The gap size was set at 2 mm, and the gap controller feature was used to produce uniform ribbons with consistent quality.

Alexanderwerk.com" Keyword Found Websites Listing ...

Used Alexanderwerk roller compactor, model WP120 V PHARMA, stainless steel construction, horizontal screw feeder with pre breaker, cantilevered rolls, flake crusher, pre granulator and fine granulator attachments, rated +/- 5g batch, 8 - 40 kg/hour continuous operation with operator control panel, portable design, 460 volt, serial

(PDF) Determination of process variables affecting drug ...

(Alexanderwerk, Remscheid, Germany). The powder feed system ... 11, 63, 93 specifically in the feeder of an Alexanderwerk WP120 roller compactor (no other devices have been tested so far). As it ...

Alexanderwerk WP120 laboratory roller compactor - Orthos

Alexanderwerk's WP120 laboratory roller compactor is an all-in-one dry granulation machine for producing free flowing granules to feed your capsule filler or tablet press. Pre-blended powder is fed into the raw material hopper where a slow turning agitator encourages its …

OPTIMIZATION OF TETRABENAZINE TABLET FORMULATION …

blend by using roll compactor (Alexanderwerk AG, Germany) to get the granules. Slugs was milled and passed through 10.0 mm S.S Screen, slow speed, knives forward using comminuting mill (M/s Ganson Ltd., India). Talc was sifted through sieve 60 and mixed with the above granules in octagonal blender for 10 minutes.

WP120 Archives - Alexanderwerk Inc

August 25, 2020 7:05 am Leave a Comment. Shown here are Alexanderwerk's pharma and nutraceutical industry roller compactor and dry granulation workhorses WP120 and WP200. If for nothing else the Covid19 crisis has brought to light a greater sense of urgency for being able to boost local production of pharma and even nutraceutical products.

Implementation of an online thermal imaging to study the ...

An Alexanderwerk WP120 (Alexanderwerk, Germany) roller compactor was used for the compaction of the lactose powder in this study. The WP120 has three systems working simultaneously: the feeding system, compaction system and milling system.

PULL TYPE TANDEM FERT. SPREADER W ROLL TARP Other Items ...

Browse our inventory of new and used PULL TYPE TANDEM FERT. SPREADER W ROLL TARP Other Items For Sale near you at TruckPaper.com. Models include . Page 1 of 1.

ALEXANDERWERK used RESALE

ALEXANDERWERK HD 114. meat grinder. Seller: Theodor Eberlei & Co.KG. Location: 26215 Wiefelstede, DE. Price: 1.850 €. Meat grinder, automatic grinder -Motor power: 4.5 / 6 KW -Motor speed: 1500/3000 rpm -Voltage: 380V -Slug -without perforated disks and knives …

(Trimethoxyphenylamino) pyrimidinyl formulations - Rigel ...

The homogenous mix is then passed through a roller compactor, such as an Alexanderwerk WP120 to produce dry granules. The dried granulated formulation produced via the wet granulation and/or roller compaction process is milled using conventional techniques and machinery.

Alexanderwerk : WP 120 Pharma test side by side comparison ...

You get what you pay for… A true success by an Alexanderwerk customer on the performance of the Alexanderwerk WP 120 Pharma Roller Compactor. A global... | October 9, 2021

Quality by design I: Application of failure mode effect ...

Granules were manufactured using an Alexanderwerk WP120 roller compactor and tablets were compressed on a Stokes B2 tablet press. In the early stages of development, prior knowledge was systematically incorporated into the risk assessment using failure mode and effect analysis (FMEA).

Pharma Compactors - Alexanderwerk Inc

Alexanderwerk Kippdorfstr. 6-24 42857 Remscheid/Germany P +49 (0) 2191 7950 F +49 (0) 2191 795350 [email protected] No liability is taken for errors, prin ng errors and technical changes. Alexanderwerk roller compactors for the pharmaceu cal industry Compac on machine Roller compactor BT 120 Pharma

(PDF) Using a Material Library to Understand the Impacts ...

The sizes of the calibr ation data set for PLS Model 1, Mo del 2 and Model 3 were 290 × 23, 290 × 5 and 290 × 27, respectively. The two response v ariables, i.e., the ribbon TS and SF, were